Product Series

Mature product, reliable quality.

QingyuanCard‑slot‑type clock server DNTS‑9

The DNTS-9 is an intelligent, high-precision satellite time‑synchronization device, specifically designed to provide a high‑accuracy time reference for automation in power systems.

Phone: 010-62893032

Product Description

 

Technical indicators

 

Project

Technical Specifications

 

 

 

 

GPS   Receive Receiver

 

Sensitivity

Cold-start acquisition sensitivity: -148 dBm

Hot-start acquisition sensitivity: -156 dBm

Reacquisition sensitivity: -160 dBm

Tracking sensitivity: -162 dBm

Positioning accuracy:

2.5  rice

During initial positioning:

32  seconds

Cold start   TTFF :

≤35  seconds

Hot start   TTFF:

≤1 second

Recapture   TTFF :

≤1 second

Timing accuracy  :

<  ±  30ns

 

 

 

Beidou Satellite

Star Reception machine

 

Sensitivity

Cold-start acquisition sensitivity: -148 dBm

Hot-start acquisition sensitivity: -156 dBm

Reacquisition sensitivity: -160 dBm

Tracking sensitivity: -162 dBm

Supports BeiDou navigation satellite signals (BeiDou-3), including B1I, B1C, and B2a service signals.

Positioning accuracy:

2.5  rice

During initial positioning:

32  seconds

Cold start   TTFF :

≤35  seconds

Hot start   TTFF:

≤1 second

Recapture   TTFF :

≤1 second

Timing accuracy  :

<  ±  30ns

Device Interface

Flexibly configured according to actual application needs.

 

Network

Interface Specification

10Base-T/100Base-TX  Adaptive, MDI/MDI‑X, automatic polarity reversal, IEEE 802.3

Agreement

ARP, ICMP, UDP, NTP, SNTP, PTP, IP, Teln and

UDP   Receiving host

16 groups, supporting broadcast and multicast, meeting the time‑synchronization requirements of an unlimited number of hosts.

 

 

 

 

 

Serial port report Text

Serial port parameters

Baud rate: 600 bps to 115,200 bps, software-configurable; data bits, parity bit, and stop bits are configurable.   Set.

 

 

Message Format (Software) Optional)

1. Q/GD001-1154-3--2005 Guangdong Power Grid Substation   GPS   Technical Specification for Satellite Time Synchronization Equipment   Formal report format;

2. Standard Design for Transmission and Transformation Projects of State Grid Corporation, 110–500 kV   Substation secondary system section (none)   Custom information) message format;

3. Standard time message format for the serial port;

4. Serial port time message format with frequency description;

5. GPZDA

Optical fiber

Time accuracy:   ±   1 ms. Signal: FTX. Single-mode, Multi-mode optional.

RS232

Time accuracy:   ±   1 ms. Signals: TX, GND.

RS485

Time accuracy:   ±   1 ms. Signals: TA, TB; each channel can drive up to 128 loads.

TTL

Time accuracy:   ±   1 ms. Signals: TX, GND.

 

 

Pulse    (PPS,   PPM,

PPH)

On time along

TTL   Level: Rising edge, rise time ≤ 50 ns; RS‑422, RS‑485: rising edge, rise   Time ≤ 50 ns; optical fiber: rising edge; static dry contact: rising edge, rise time ≤   1 μs.

Level pulse width

10 ms to 800 ms   The software is configurable, with a step size of 1 ms.

Optical fiber

Time accuracy:   ±   1 μs. Signal: FTX. Single-mode and multi-mode options available.

RS232

Time accuracy:   ±   1 μs. Signals: TX, GND.

RS485

Time accuracy:   ±   1 μs. Signals: TA, TB. Each channel can drive up to 128 loads.

TTL

Time accuracy:   ±   1 μs. Signals: TX, GND.

OC gate output

Time accuracy:   ±   1 μs. Signals: C, E. C   External applied voltage   V CE: Maximum   300 VDC. CE

Allowable collector–emitter current I_CE: maximum   200 mA.

IRIG-B

Symbol information

Symbol width: 1 per second   Frame, each frame contains 100   One symbol, with each symbol lasting 10 ms.

The time‑code information includes: time zone information, time quality information, and leap seconds. Identification information, SBS   Information

Optical fiber

Time accuracy:   ±   1 μs. Signal: FTX. Single-mode and multi-mode options available.

RS232

Time accuracy:   ±   1 μs. Signals: TX, GND.

RS485

Time accuracy:   ±   1 μs. Jitter time: ≤10 0ns. Signals: TA, TB. Each channel can support up to   Drives 128 loads.

TTL

Time accuracy:   ±   1 μs. Signals: TX, GND.

 

IRIG-BAC

Time accuracy:   ±20 μs, balanced mode   600 Ω   , it can drive at 13 Vpp   330 Ω   The above   Purely resistive load, output amplitude: 2 ~   13 Vpp, continuously software-adjustable; modulation ratio: 2 to 8, software-controlled.   Adjustable; zero-crossing time offset: -30 to 30   microseconds Software-adjustable (used to enhance AC modulation)   The time demodulation accuracy of the code square.

 

 

 

 

DCF77

Optical fiber

Time accuracy:   ±   1 μs. Signal: FTX. Single-mode and multi-mode options available.

RS232

Time accuracy:   ±   1 μs. Signals: TX, GND.

RS485

Time accuracy:   ±   1 μs. Signals: TA, TB. Each channel can drive up to 128 loads.

TTL

Time accuracy:   ±   1 μs. Signals: TX, GND.

OC gate output

Time accuracy: ±   1 μs. Signals: C, E. CE   External applied voltage    CE: Maximum   300 VDC. C   interval

Allowable Collector-Emitter Current I_CE: Maximum   200 mA.

NTP/SNTP

Time accuracy: 100 μs, standard 10/100BaseT   Ethernet   RJ45 interface/100BaseT   Optical fiber mouth

PTP (IEEE 1588)

Time accuracy: 100 ns, standard 10/100BaseT   Ethernet   RJ45 interface/100BaseT   Fiber optic port

Timekeeping accuracy

Timekeeping accuracy: 1 μs/hour; for applications requiring higher precision, the crystal oscillator can be replaced.

Crystal oscillator type (to be specified when placing the order)

5×10 -8   (1 μs/hour, 24   μs/   Day)    2×10 -11   (1.2ns/   minutes, 1.728 μs/   Day)   Choose between

Alarm contact type

Relay dry contact, 2+1   Alarm output (device fault alarm, loss-of-synchronization alarm, and device power-off alarm)   Police ), Contact rating: 10 A (NO) / 250 VAC, 5 A (NO) / 30 VDC, 3 A (NC) / 30 VDC.

 

Insulation   Can

Insulation resistance

The insulation resistance between each conductive circuit and ground is greater than 500 MΩ.

Dielectric strength

Circuit with a rated insulation voltage greater than 60 V: 1.5 kV   Power-frequency voltage or  2.1kV  Direct current voltage   For circuits with a rated insulation voltage ≤ 60 V: 500 V   Power-frequency voltage or  710V  Direct current voltage

Impulse voltage

Circuit with a rated insulation voltage greater than 60 V: 5 kV

For circuits with a rated insulation voltage ≤ 60 V: 1 kV

 

 

 

 

 

 

EMC

Electrostatic Discharge Immunity

Air discharge:   ±15 kV; Contact discharge:   ±8kV

Radiofrequency electromagnetic field radiation   Immunity

10 V/m; 80 MHz–1 GHz; Modulation: 80% AM

Electrical Fast Transient Pulse   Group immunity to interference

±4 kV, 2.5 kHz (power supply, alarm output) );   ±2 kV, 5 kHz (communication)

Surge (impulse) immunity degree

Common-mode: ±4 kV, Differential-mode: ±2 kV

Power-frequency magnetic field immunity

Steady magnetic field: 30 A/m; transient magnetic field (3 s): 300 A/m

Pulse magnetic field immunity

Magnetic field strength: 300 A/m

Damped oscillating magnetic field resistance   Disturbance degree

Magnetic field strength: 30 A/m

Damped oscillatory wave immunity   degree

Common-mode: ±2.5 kV; differential-mode: ±1 kV; 1 MHz, 100 kHz

MTBF

>350000h