02
2024
-
09
Zhongxin Chuangwei provides NTP clock synchronization equipment to the Affiliated Hospital of Jiangxi University of Traditional Chinese Medicine.
Zhongxin Chuangwei provides NTP clock synchronization equipment to the Affiliated Hospital of Jiangxi University of Traditional Chinese Medicine.

Recently, the Affiliated Hospital of Jiangxi University of Traditional Chinese Medicine issued a request for a clock synchronization system. Beijing Zhongxin Chuang Company responded proactively by developing a detailed solution and recommending its self‑developed and manufactured DNTS‑9 model as the bid‑winning product. Following a fiercely competitive bidding process, Zhongxin Chuang stood out thanks to its high‑quality products and comprehensive after‑sales service, ultimately securing the contract for the time‑server project at the Affiliated Hospital of Jiangxi University of Traditional Chinese Medicine.
The Affiliated Hospital of Jiangxi University of Traditional Chinese Medicine (Jiangxi Provincial Hospital of Traditional Chinese Medicine and Jiangxi Provincial Orthopedic Hospital) is a Grade III, Level A TCM hospital. It serves as the leading and central institution for TCM medical care, education, research, and preventive health services in Jiangxi Province.
Jiangxi University of Traditional Chinese Medicine Affiliated Hospital conducted an in-depth evaluation of the DNTS‑9 time server, which was independently developed by Zhongxin Chuang. The results consistently exceeded the specified performance parameters, and the hospital expressed high satisfaction with both our product quality and after-sales service, leading to a successful procurement and deployment.
The DNTS-9 network time server, developed by Beijing Zhongxinchuang Technology Co., Ltd., is an intelligent, high-precision NTP network time server. The DNTS-9 obtains standard time information from navigation and positioning satellite systems such as GPS, BeiDou, GLONASS, and Galileo, and provides standard time services over the network via NTP/SNTP or other network protocols. In addition to serving as a primary-level network time synchronization device, the DNTS-9 can also function as a secondary-level time server, enabling more effective time synchronization in large-scale network environments. It can supply precise standard time signals to systems requiring accurate timing, including distributed networks, computer security systems, file management systems, e‑commerce systems, online B2B platforms, and cloud database storage and maintenance. The DNTS-9 has been successfully deployed in government, finance, mobile communications, public security, petroleum, electric power, transportation, industrial, and national defense sectors. Installation and operation of the DNTS-9 are extremely straightforward: simply connect the satellite receiving antenna and link the network port to a network switch to achieve time synchronization across all devices on the network.
| Network protocol |
NTP v1, v2, v3, and v4 (RFC 1119 and RFC 1305), SNTP (RFC 2030), Authentication (RFC 1321), Telnet (RFC 854), UDP NTP Unicast, Broadcast, Multicast, Autokey, TIME (RFC 868), FTP (RFC 959), DAYTIME (RFC 867), DHCP (RFC 2131) |
| HTTP/SSL/HTTPS (RFC 2616), SSH/SCP (Internet Draft), SNMP v1, v2c, and v3, MIB II (RFC 1213), RSA asymmetric encryption, MD5 authentication, SHA authentication, AES encryption, DES encryption, RC4 encryption. |
|
| IPv4, IPv6, IPv4/IPv6 Hybrid |
|
| Timekeeping mode |
Supports NTP Peer Client/Server Broadcast Multicast |
| Server performance |
GNSS reference mode, Tier‑1 network time server, with an internal synchronization accuracy of 20 ns. |
| User terminal synchronization timing accuracy: 0.1–2 ms (typical value on a local area network) |
|
| User capacity: Supports tens of thousands of clients. |
|
| NTP request rate: 25,000 requests per second (per network port) |
|
| It can be used as a client to synchronize with other NTP network time servers. |
|
| Supports logging up to 100,000 entries and allows storage capacity to be expanded as needed. |
|
| Receiver |
72-channel timing‑grade GNSS receiver, multi‑constellation GPS/BeiDou/GLONASS, supports RAIM, with optional CDMA support. |
| UTC synchronization accuracy: 20 ns (RMS) |
|
| Tracking and lock‑on sensitivity can reach −166 dBm. |
|
| Timekeeping function |
Temperature‑compensated crystal oscillator (optional, depending on model): Timing accuracy: standard configuration better than 8.6 µs/day (configurable upgrades available to meet specific requirements). |
| Rubidium atomic clock (optional depending on model): Timing accuracy: standard configuration better than 500 ns/day (configurable upgrades available to meet varying requirements). |
|
| Front panel |
VFD high-brightness LCD display |
| Displays GPS/BD satellite acquisition status, time, number of GPS/BD satellites, IP addresses of each network port, system operating status, and more. |
|
| 6 tri-color indicator lights: PWR, ANT, SAT, LOCK, NTP, ALARM |
|
| Signals indicating power, antenna, satellite, lock, timing, and alarms. |
|
| Rear panel |
GNSS antenna input: BNC, with 1–2 channels optional. |
| NTP network port: 1–10 ports, with optional 10/100/1000 Mbps or 10 Gigabit Ethernet interfaces. |
|
| Console-RS232: 1 port |
|
| USB Interface: 1–8 channels optional, supports USB 2.0/3.0, with backup, restore, and upgrade functions. |
|
| TOD: DB-91 bus, RS232/RS485 levels, capable of outputting time, position, number of satellites, and other information. |
|
| ALARM dry-contact alarm: 1–6 pairs optional, with alarms for satellite, power supply, antenna, port capacity, and more. |
|
| 10M output: BNC, 1 channel, selectable sine wave or square wave, impedance: 50 ohms; frequency accuracy: <1E-12 |
|
| 1 PPS output: BNC, TTL level, accuracy ≤ 10 ns (RMS) |
|
| Dimensions: 1U/2U chassis |
With 18 years of industry experience, our company has established a strong corporate reputation and brand image, serving clients in the healthcare sector, including:
Peking Union Medical College Hospital, The First Affiliated Hospital of China Medical University, Cancer Hospital of the Chinese Academy of Medical Sciences, Tiantan Hospital of Capital Medical University, Peking University People’s Hospital, Beijing Children’s Hospital, China-Japan Friendship Hospital, Peking University Third Hospital, Shanghai First People’s Hospital, Shandong Provincial Public Security General Hospital, Rencheng District People’s Hospital in Jining City, The Affiliated Hospital of Harbin Medical University, PLA No. 187 Hospital, Kunming First People’s Hospital, Fujian Provincial Hospital, Inner Mongolia Baogang Hospital, Henan Provincial Second People’s Hospital, The First Affiliated Hospital of Henan University of Science and Technology, Wuxi Municipal Hospital Management Center, Inner Mongolia Health Department and Linggeer County Health Bureau, Linzi District Maternal and Child Health Care Institute, Qufu Municipal People’s Hospital, Datong Municipal Second People’s Hospital, JianShi County People’s Hospital in Hubei Province, Beihua University Affiliated Hospital, Suzhou Traditional Chinese Medicine Hospital, Yueyang Municipal Traditional Chinese Medicine Hospital, Ar Horqin Banner Hospital, Jiujiang Maternal and Child Health Care Institute, Luoyang Sixth People’s Hospital, Ar Horqin Banner Traditional Chinese Medicine Hospital, Dongying Municipal People’s Hospital, Fushun Central Hospital, Guangxi Medical University Affiliated Hospital, Linshu County People’s Hospital, Pengshui County People’s Hospital, Yanjiao People’s Hospital in Sanhe City, Zhongwei Municipal Traditional Chinese Medicine Hospital, Jiangjin District Central Hospital in Chongqing, Jungar Banner Central Hospital, Taizhou Hospital, Ili–Jiangsu Hospital, Fushun Central Hospital, Australian People’s Hospital, Quzhou Municipal Hospital, and others.
The choice of numerous departments and enterprises reflects recognition of Zhongxin Chuang’s products and services. By working in close collaboration with partners across all sectors, we are jointly advancing toward win-win outcomes for businesses and society alike.
Next page